Product Description Model Overall dimension(mm) Install dimension(mm) Drawing ACEBDd 5.5KW-55KW15229221592269M6175KW-110KW274408260160385M82132KW-315KW440530290320530M83The Quick Setup menu allows you to quickly confifigure the soft starter for common applications. The soft starter selects the......Keywords:15 Years Factory 3 Phase 220V/380V/690V 5.5kw to 600kw Soft Starter AC Asynchronous Motor, Spanish Language, Russian Language

Send Inquiry

Product Description

Product Description
15 Years Factory 3 Phase 220V/380V/690V 5.5kw to 600kw Soft Starter AC Asynchronous Motor
15 Years Factory 3 Phase 220V/380V/690V 5.5kw to 600kw Soft Starter AC Asynchronous Motor
15 Years Factory 3 Phase 220V/380V/690V 5.5kw to 600kw Soft Starter AC Asynchronous Motor
15 Years Factory 3 Phase 220V/380V/690V 5.5kw to 600kw Soft Starter AC Asynchronous Motor
 
 
15 Years Factory 3 Phase 220V/380V/690V 5.5kw to 600kw Soft Starter AC Asynchronous Motor
15 Years Factory 3 Phase 220V/380V/690V 5.5kw to 600kw Soft Starter AC Asynchronous Motor
15 Years Factory 3 Phase 220V/380V/690V 5.5kw to 600kw Soft Starter AC Asynchronous Motor
 
Model
 Overall dimension(mm)
 
 
 Install dimension(mm)
 
 
 
Drawing
 
A
C
E
B
D
d
 
5.5KW-55KW
152
292
215
92
269
M6
1
75KW-110KW
274
408
260
160
385
M8
2
132KW-315KW
440
530
290
320
530
M8
3
The Quick Setup menu allows you to quickly confifigure the soft starter for common applications. The soft starter selects the
parameters related to the application and recommends typical settings. You can adjust each parameter according to your actual
needs.
Always set parameter 1A, the rated current of the motor to match the rated current indicated on the motor plate. The recommended
value is the minimum rated current of the starter.
On the screen, the highlighted value is the recommended value, and the value marked with is the loaded value.
--------------------------------------------------------------
*ApplicationCentrifugal pump
-ParameterMotor rated current Starting method Adaptive starting curve Start ramp time Stop mode Adaptivestop curve Stop
time
-Suggested ValueDepending on model Adaptive Control Early acceleration 10 seconds Adaptive Control Deceleration 15 seconds
*ApplicationSubmersible pump
-ParameterMotor rated current Starting method Adaptive starting curve Start ramp time Stop mode Adaptivestop curve Stop
time
-Suggested ValueDepending on the model. Adaptive Control Speed up early. 5 seconds Adaptive Control After decelerating. 5
seconds
*ApplicationDamped fan
-ParameterMotor rated current Starting method Current limit
-Suggested ValueDepending on modelConstant current350%
* ApplicationUndamped fan
-ParameterMotor rated current Starting method Adaptive starting curve Start ramp time Starting limit time Locked rotor time
-Suggested ValueDepending on model Adaptive Control Constant acceleration 20 seconds 30 seconds 20 seconds
* ApplicationScrew compressor
-ParameterMotor rated current Starting method Start ramp time Current limit
-Suggested ValueDepending on modelConstant current5 seconds400%
*ApplicationReciprocating compressor
-ParameterMotor rated current Starting methodStart ramp time Current limit
-Suggested ValueDepending on model Constant current 5 Second 450%
*ApplicationConveyor belt
-ParameterMotor rated current Starting method Start ramp time Current limit Stop mode Adaptive stop curve Stop time
-Suggested ValueDepending on model Constant current 5 seconds 400% Adaptive Control Constant deceleration. 10 seconds
*ApplicationRotary crusher
-ParameterMotor rated current Starting method Start ramp time Current limit Starting limit time Locked rotor time
-Suggested ValueDepending on model Constant current 10 seconds 400% 30 seconds 20 seconds
*ApplicationJaw Crusher
-ParameterMotor rated current Starting method Start ramp time Current limit Starting limit time Locked rotor time
-Suggested ValueDepending on model Constant current 10 seconds 450% 40 seconds 30 seconds
 
15 Years Factory 3 Phase 220V/380V/690V 5.5kw to 600kw Soft Starter AC Asynchronous Motor
15 Years Factory 3 Phase 220V/380V/690V 5.5kw to 600kw Soft Starter AC Asynchronous Motor
15 Years Factory 3 Phase 220V/380V/690V 5.5kw to 600kw Soft Starter AC Asynchronous Motor
Company Profile
15 Years Factory 3 Phase 220V/380V/690V 5.5kw to 600kw Soft Starter AC Asynchronous Motor
Product Line
15 Years Factory 3 Phase 220V/380V/690V 5.5kw to 600kw Soft Starter AC Asynchronous Motor
Certifications
15 Years Factory 3 Phase 220V/380V/690V 5.5kw to 600kw Soft Starter AC Asynchronous Motor
15 Years Factory 3 Phase 220V/380V/690V 5.5kw to 600kw Soft Starter AC Asynchronous Motor
Product packaging
15 Years Factory 3 Phase 220V/380V/690V 5.5kw to 600kw Soft Starter AC Asynchronous Motor
Our Advantages
15 Years Factory 3 Phase 220V/380V/690V 5.5kw to 600kw Soft Starter AC Asynchronous Motor
FAQ
15 Years Factory 3 Phase 220V/380V/690V 5.5kw to 600kw Soft Starter AC Asynchronous Motor

Product Tag

Related Category

Send Inquiry

Please Feel free to give your inquiry in the form below. We will reply you in 24 hours.
验证码,看不清楚?请点击刷新验证码